Honeywell ra117a1047 manual






















 · I just replaced a Honeywell RAA burner control. All the wires appear to be connected properly. I turned the thermostat up, turned the power back on set the friction clutch. Nothing's happening. I tried tripping the safety switch, and still nothing. Can't find a basic manual that tells me how to re-light it. Honeywell RAA ; Manual reset of safety switch required after ignition failure completely shuts off main burner ; Include manual trip safety switch to assure burner shutdown during servicing ; Mount with flange for mounting on curved or flat surfaces ; Use with line voltage or 24 Vac Control Circuit › See more product details4/5(17). This is a BRAND NEW Honeywell Protectorelay " Insertion Control Board/Limit. The Honeywell part # is RAA Control comes with instructions. Thanks for looking and good luck!Replaces Old Control Board #s: Powered by The free listing tool. Lis.


GeniSys™ V Oil Burner Control. The Beckett GeniSys™ Advanced Burner Control is a VAC primary safety control for residential and light commercial oil burners used in boiler, furnace, and water heater applications. The GeniSys™ is used with a suitable cad cell flame sensor to control the oil burner motor, igniter, and optional. Honeywell RAA Protectorelay Oil Burner Control Features: Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat. Solid state flame sensing circuit. LED on terminal strip indicates system lockout. Remote lockout indication available on some models. Enclosed safety switch with external reset. On by (mod) - get the IO manuals for your stack relay replacement using the Honeywell RA a Cad Cell sensor @David, see also RESET SWITCH, CAD CELL RELAY and OIL BURNER MANUALS to download PDF files of installation instructions for these controls. On - by (mod) -.


Honeywell RAA ; Manual reset of safety switch required after ignition failure completely shuts off main burner ; Include manual trip safety switch to assure burner shutdown during servicing ; Mount with flange for mounting on curved or flat surfaces ; Use with line voltage or 24 Vac Control Circuit › See more product details. This is a BRAND NEW Honeywell Protectorelay " Insertion Control Board/Limit. The Honeywell part # is RAA Control comes with instructions. Thanks for looking and good luck!Replaces Old Control Board #s: Powered by The free listing tool. RAA/U. Include manual trip safety switch to assure burner shutdown during servicing. Honeywell International Inc.

0コメント

  • 1000 / 1000